High-permeability ferromagnetic shielding materials redirect magnetic flux lines rather than blocking or destroying them. By providing a low-reluctance path, the alloy draws the magnetic field into its wall thickness and routes it around the protected volume. Technical values for shielding alloys are established from standardized test samples, with minor production variations occurring due to gauge thickness, annealing duration, and furnace temperature tolerances.
Because shield performance depends on ambient field strength, shield geometry, and material thickness, preliminary design calculations start by estimating the induced flux density inside the shield wall:
- B = Flux density inside the shield material (gauss)
- D = Diameter or diagonal dimension of the shield (inches)
- Ho = Ambient or incident magnetic field strength (gauss)
- t = Wall thickness of the shield (inches)
Once B is calculated, consult the B-H and Flux Density vs. Permeability (μ) curves for the selected alloy (such as CO-NETIC® AA or NETIC® S3-6) to verify the material will not saturate and to determine its operating permeability at that flux level. Approximate shielding attenuation is then given by:
Design Example: For a 2" diameter cylinder exposed to a 2 gauss ambient field using 0.014" thick material:
At B = 357 gauss, material permeability (μ) ≈ 140,000
A = (140,000 × 0.014") / 2" = 980